§ 14.46.030. Section C104 Amended—Special occupancy and exit requirements for Agri-com.


Latest version.
  • International Building Code Section C104 is amended, and Sections C104.1, C104.2, C104.2.1, C104.2.2, C104.2.3, C104.2.4, C104.2.5, C104.3, C104.4, C104.5 and C104.6; and Table C104.5 are added to read as follows:

    C104 Special occupancy and exit requirements for Agri-com.

    C104.1 Occupant load. Agri-com building occupant load limits shall be as designated by the hearing examiner but in no case shall exceed three hundred persons. The occupant load for riding arenas/stables will be determined by counting one person for each stall, one person at the entrance, two trainers in the riding arena with the balance of the maximum occupant load to be available for spectators. The occupant load for other animal training services shall be determined based on a calculation using five hundred square feet per occupant.

    C104.2 Exits.

    C104.2.1 No less than two exits shall be provided for the arena area.

    C104.2.2 Exit distribution shall meet the requirements of Chapter 10.

    C104.2.3 One exit shall be provided at each end of any stall isle.

    C104.2.4 Doors shall comply with Chapter 10.

    C104.2.5 Exit signs shall comply with Chapter 10.

    C104.3. Accessibility. Agri-com buildings shall be accessible as required in section Chapter 11 for U structures.

    C104.4 Bleacher and grandstands. Bleacher and grandstands shall comply with Chapter 10.

    C104.5 Fixture requirements for Agri-com. Agri-com buildings shall have plumbing fixtures as per Table C104.5. In occupancies serving fifteen or fewer persons, one toilet facility designed for use by no more than one person at a time shall be permitted for use by both sexes.

    C104.6 Fees. A permit shall not be valid until the fees prescribed by law have been paid, nor shall an amendment to a permit be released until the additional fee, if any, has been paid. Fees shall be assessed in accordance with the provisions of this section and shall offset expenditures necessary to fund the related operation of the department. Fees shall be as set forth in the department fee schedule.

    Table C104.5

    Type of
    Building or
    Occupancy
    Water Closets Lavatories Drinking
    Fountain
    Male Female Male Female
    Group U
    Agri-com
    1: 1-75 1: 1-40 One per 2 water closets One when occupant load exceeds 30
    2: 76-150 2: 41-75
    3: 76-150

     

(Ord. No. 14388, § 1(Attach. 1), 8-3-2010; Ord. No. 14906, § 1(Att. A), 6-25-2013; Ord. No. 15648 , § 1(Att. A, § I), 8-7-2018)